Widely used in operation room, emergency room, orthopedics and surgery department.
Main merits:
Real digital high frequency host can got the clearest and richest image with least radiation dose, which great reduce the harm to clinical doctors and patients from radiation.
Adopts unique double screen display board, making operation intuitive, easy and reliable.
Vertical translation, anteroposterior motion and rotation of C-Arm are power-driven.
Micro-computer controlled and equipped with fault self-diagnosis function make maintenance easy.
With digital interface design and Picture Collection & Storage Workstation, the image can be browsed, adjusted, post processed, storage and transmitted. Provide a short-cut for your heavy file management.
Widely used in medical education, scientific research, medical institution for X-ray radiography and diagnosing
Especially applied in traumatic disorders and the hospitals which having a big mount of mobile radiography such as bedside radiography in the image department intensive care unit, operation room, newborn ward, orthopedics ward, general ward and so on.
Upgrading digital image system
Hard disc can storage statics 100 thousand images.
Many images can display at same time
Image processing function: image rotating and overturn, brightness contrast adjustment.
Laser printer can print diagnosis report.
Parameters and Configuration of Mobile High
Â
Frequency C-Arm X-ray Machine
Â
Â
Â
NO. | Item | 3.5KW parameters |
 |  |  |
1 | Generator power/frequency | 3.5KW/40KHZ |
 |  |  |
2 | Radiograph KV | 40-110KV |
 |  |  |
3 | Radiograph mA | 30-70mA |
 |  |  |
4 | Fluoroscopy KV | 40-110KV |
 |  |  |
5 | Fluoroscopy mA | 0.3-3.2mA |
 |  |  |
6 | Pulse fluoroscopy | Â | 0.1-8mA |
 |  |  |  |
7 | Focus size |  | 0.6×1.5mm(fixed anode) |
 |  |  |  |
8 | Anode thermal capability | Â | 30KJ(40KHU) |
 |  |  |  |
9 | Combined   machine   head | thermal | 500KJ(667KHU) |
 |  |  | |
 | capability |  |  |
 |  |  |  |
*10 |  |  | Can rotate 360°around the X-ray centerline, open and close |
 | collimator |  | lightly, flexibly and reliably |
 |  |  | |
 |  |  | |
11 | Distance  between  focus  and  image |  | |
 | intensifier(SID) |  | 1004mm |
 |  |  | |
 |  |  |  |
*12 | C-arm depth | Â | 749mm |
 |  |  |  |
13 | C-arm width | Â | 805mm |
 |  |  |  |
14 | C-arm arc full balance slide |  | 125° |
 |  |  |  |
15 | C-arm rotation(motor) |  | <±180° |
 |  |  |  |
*16 | Vertical translation(motor) | Â | 478mm |
 |  |  |  |
17 | Level shift(motor) | Â | 202mm |
 |  |  |  |
18 | Horizontal hunting |  | >±12.5° |
 |  |  |  |
*19 | Image intensifier | Â | 9" Japan TOSHIBA intensifier |
 |  |  |  |
20 | CCD | Â | CCD camera |
 |  |  |  |
21 | monitor | Â | 14" high definition monitor |
 |  |  |  |
22 | board | Â | Double operation board,failure code displayed automatically |
 |  |  |  |
23 |  |  | 8   images   storage,   freeze   frames,   multiple   levels   of |
 | Image storage |  |  |
 |  |  | noise,screen with dual display feature |
 |  |  |  |
24 | Power condition | Â | 220V,50Hz,20A |
 |  |  |  |
25 | Power capability | Â | 4KVA |
 |  |  |  |
Standard Configuration
Â
Item | Model |
 |  |
X-TUBE | IMD/XR04 |
 |  |
Combined machine head | E-40 HF IMD/XR04 |
 |  |
Image intensifier | E5804HD-P3(TOBASHI) |
 |  |
Medical X-ray TV | DP-808 |
 |  |
Image processor | DP-808 |
 |  |
Development Milestone
Â
1) In 1952, we produced China's 1st set of 200mA medical diagnostic X-ray machine, with name of "Shanghai precision medical equipment factory

2) In 1970, the company was relocated from Shanghai to Neijiang City, Sichuan
Â
Â
Â
Bd Test Package is a diagnostic test for a sterilizer vacuum system.In particular,this test can assess an insufficient vacuum condition,meaning that air from the sterilizer cabinet is not completely removed or air leaks from the seal gasket of the door remain in the sterilizer cabinet.This residual air prevents the steam from penetrating the contents of the sterilizer cabinet during the steam exposure phase of the sterilization process.Remove the paper containing the sterilization Indicator tape from the test pack and observe the uniform color change of the indicator line in the tape.A non-uniform or shallow indicator line appears in the center of the paper (where the tape crosses each other) indicating that the penetration of steam into the center of the test pack is blocked. This non-uniformly consistent indicator indicates that steam cannot reach the center of the test pack due to the presence of residual air in the sterilizer cabinet.
Bd Test Package,Medical Test Package,Disposable Medical Test Package,Pressure Steam Test Package
Henan Sanqiang Medical Equipment Liability Co.,Ltd , http://www.sterilizers-china.com