Bovine Immunoglobulin E (IgE) ELISA Kit Instructions
· This kit is used for quantitative determination of bovine immunoglobulin E (IgE) in serum, plasma, tissue, cell supernatant and related liquid samples in vitro.
· Validity period: 6 months · Storage conditions: 2-8 ° C
Experimental principle of bovine immunoglobulin E (IgE) ELISA kit
The kit uses a double antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). The coated microcapsules, which were previously coated with human visfatin (Visfatin) capture antibody, were sequentially added with specimens, standards, and HRP-labeled detection antibodies, and were incubated and thoroughly washed. Using the substrate TMB to develop color, TMB is converted to blue under the catalysis of peroxidase and converted to the final yellow color by the action of an acid. The color depth is positively correlated with the human visfatin (Visfatin) in the sample. The absorbance (OD value) was measured at 450 nm using a microplate reader to calculate the sample concentration.
Bovine Immunoglobulin E (IgE) ELISA Kit Sample Processing and Requirements
1. Serum : Whole blood samples should be placed at room temperature for 2 hours or 4 °C overnight, centrifuged at 1000g for 20 minutes, the supernatant can be detected, or the specimens can be stored at -20 ° C or -80 ° C, but should be avoided repeatedly melt.
2. Plasma : EDTA or heparin can be used as anticoagulant. The specimen should be centrifuged at 2-8 °C for 1000 minutes within 20 minutes after collection, or the specimen should be stored at -20 °C or -80 °C, but repeated freezing and thawing should be avoided. .
3. Cell culture supernatant or other biological specimens : centrifuge at 1000g for 20 minutes, take the supernatant to detect, or store the specimen at -20 °C or -80 °C, but avoid repeated freezing and thawing.
Note: Specimen hemolysis will affect the final test results, so hemolysis specimens should not be tested.
Reagents and equipment that are needed but not provided
- Microplate reader (450nm)
- High-precision sampler and tip: 0.5-10uL, 2-20uL, 20-200uL, 200-1000uL
- 37 ° C incubator
- Distilled or deionized water
Precautions
- Incubation is carried out strictly in accordance with the specified time and temperature to ensure accurate results. All reagents must reach room temperature 20-25 °C before use. Store the reagents refrigerated immediately after use.
- Incorrect cleaning can result in inaccurate results. Make sure to drain the liquid in the well as much as possible before adding the substrate. Do not let the micropores dry during the incubation process.
- Eliminate residual liquid and fingerprints at the bottom of the board, otherwise it will affect the OD value.
- The substrate coloring solution should be colorless or very light, and the substrate liquid that has turned blue cannot be used.
- Avoid cross-contamination of reagents and specimens to avoid erroneous results.
- Avoid direct exposure to strong light during storage and incubation.
- After balancing to room temperature, the sealed bag is opened to allow water-repellent drops to condense on the cold slats.
- Any reagents should not be exposed to strong gases emitted by bleaching solvents or bleaching solvents. Any bleaching component will destroy the biological activity of the reagents in the kit.
- Cannot use expired products.
- If the disease is likely to spread, all samples should be managed and the sample and test device processed in accordance with the prescribed procedures.
Reagent preparation
The kit should be taken out of the refrigerated environment and should be balanced at room temperature before use.
Dilution of 20× Wash Buffer: Distilled water was diluted 1:20, ie 1 part of 20× Wash Buffer plus 19 parts of distilled water.
Steps
- The required slats were taken out from the aluminum foil pouch after equilibrating for 20 min at room temperature, and the remaining slats were sealed back to 4 ° C with a ziplock bag.
- Set standard and sample wells, standard wells with different concentrations of standard 50μL;
- Add 50 μL of the sample to be tested to the sample well; blank holes are not added.
- In addition to the blank wells, 100 μL of horseradish peroxidase (HRP)-labeled detection antibody was added to each well of the standard well and the sample well, and the reaction well was sealed with a sealing plate, and incubated at 37 ° C in a water bath or incubator for 60 min.
- Discard the liquid, pat dry on the absorbent paper, fill each well with the washing solution (350 μL), let stand for 1 min, remove the washing solution, pat dry on the absorbent paper, and repeat the washing 5 times (can also be washed with a washing machine) .
- 50 μL of each of the substrates A and B was added to each well, and incubated at 37 ° C for 15 min in the dark.
- 50 μL of the stop solution was added to each well, and the OD value of each well was measured at a wavelength of 450 nm within 15 min.
Experimental result calculation
The OD value of the tested standard is the abscissa, the concentration value of the standard is the ordinate, the standard curve is drawn on the coordinate paper or with the relevant software, and the linear regression equation is obtained, and the OD value of the sample is substituted into the equation to calculate the sample. concentration.
Kit performance
- Detection range: 3.75 ng/mL – 120 ng/mL.
- Sensitivity: The minimum detection concentration is less than 0.1 ng/mL.
- Specificity: Does not cross-react with other soluble structural analogs.
- Repeatability: The intra-plate variation coefficient is less than 10%, and the inter-plate variation coefficient is less than 15%.
Bovine immunoglobulin E (IgE) ELISA kit related product recommendation:
Horse defensin β2 (DEFβ2) ELISA kit
Rat Interleukin-17 (IL-17) ELISA Kit
Bovine Histamine (HIS) ELISA Kit
Human crypto-heat protein (NLRP3) ELISA kit
Human Chlamydia pneumoniae antibody IgA (CpnIgA) ELISA kit
Bovine Phospho-Adenine-activated Protein Kinase (pAMPK) ELISA Kit
Human anaphylatoxin/complement fragment 4 (C4a) ELISA kit
Human macrophage inflammatory protein 1β (MIP-1β/CCL4) ELISA kit
Rat Matrix Metalloproteinase 7 (MMP-7) ELISA Kit
Human Myocardial Repeat Protein 1 (ANKRD1) ELISA Kit
Human type I collagen (ColI) ELISA kit
Rabbit soluble P-selectin ELISA kit
Mouse alanine aminotransferase (ALT) ELISA kit
Bovine Sialic Acid (SA) ELISA Kit
Rat E-selectin (SELE) ELISA kit
Human β2 integrin (integrinβ2/CD11+CD18) ELISA kit
Human anti-myelin antibody IgA (anti-myelinAb) ELISA kit
Canine apolipoprotein C1 (APOC1) ELISA kit
Porcine somatostatin receptor 5 (SSTR5) ELISA kit
Rat immunoglobulin-like loop and epidermal growth factor-like domain tyrosine kinase 2 (Tie2) ELISA kit
Canine Parathyroid Hormone (PTH) ELISA Kit
Goat IL-1α (IL1α) ELISA Kit
Plant Green Fluorescent Protein (GFP) ELISA Kit
Bovine Interleukin 10 (IL-10) ELISA Kit
Fish isocitrate dehydrogenase (ICD) Elisa kit
Rat Matrix Metalloproteinase 8 (MMP-8) ELISA Kit
Microbial uridine diphosphate glucose pyrophosphorylase (UGP) ELISA kit
Porcine hypoxia-inducible factor-1α (HIF-1α) ELISA kit
Mouse glutathione thiotransferase (GST) ELISA kit
Human Rho-associated coiled coil protein kinase 2 (Rock-2) ELISA kit
Porcine procalcitonin (PCT) ELISA kit
Rat Pepsin ELISA Kit
Human vascular endothelial growth factor (VEGF) ELISA kit
Human nitric oxide synthase (NOS) ELISA kit
Human L amino acid oxidase (LAO) ELISA kit
Porcine eosinophil chemotactic factor (ELISA) kit
Human prostaglandin D2 (PGD2) ELISA kit
Human Matrix Metalloproteinase 7 (MMP-7) ELISA Kit
Mouse quiescence Q6 thiol oxidase 1 (QSOX1) ELISA kit
Human B cell activating factor (BAFF) ELISA kit
Human anti-sialyl glycoprotein receptor antibody (anti-ASGPR) ELISA kit
Bovine Reovirus Antibody (RV Ab) ELISA Kit
Rat E-cadherin; epithelial cadherin (E-Cad) ELISA kit
Human Mycoplasma pneumoniae antibody (MP-Ab) ELISA kit
Bovine sulfite oxidase (SUOX) ELISA kit
Human soluble leptin receptor (sLR) ELISA kit
Goat malondialdehyde (MDA) ELISA kit
Human Apelin36 (AP36) ELISA Kit
Human urokinase-type plasminogen activator receptor (uPAR) ELISA kit
Mouse purine nucleotide phosphorylase (PNP) ELISA kit
Human α/β Interferon Receptor (IFN-α/βR) ELISA Kit
Bovine immunoglobulin E (IgE) ELISA kit for details, please consult our sales customer service hotline -021-60520062, 18721729907 QQ, welcome your inquiry, request for instructions, inquiry message form, telephone, online customer service QQ, send E-mail can be. Keshun Bio is a professional high-quality Elisa kit, production, supplier, we will be sincere, please rest assured to buy! Note: All products of the company are for scientific research only and should not be used for clinical purposes.
Waterproof Fitting With LED Tube
LED Waterproof Lamp Fitting,Waterproof LED batten light,Led Tube Waterproof Fitting,waterproof lamp holder,waterproof bulb holder,Waterproof fitting 5ft for LED tubes
Ningbo Wellway Optoelectronic Technology Co.,Ltd , https://www.wellwayopto.com